You need high pressure breathing air? Why does it need purifying? Without purification, air from a piston compressor conforms in no
way with the air quality standards required by divers; it is
saturated with moisture, contains oil vapours and may taste and
smell of impurities.
Therefore, an air processing system is of prime importance.
Without air purification, serious damage to your health and
equipment may ensue. Equipment damage includes cylinder corrosion,
equipment malfunctions through impurities and iced up, free flowing
regulators. Costly repairs and maintenance are some of the
consequences. Also hazardous microorganisms may inhabit the
cylinder.
The quality of breathing air is largely based on the purification systems and the design of the compressor block. We have 55 years of high pressure experience and know-how - that pays off!
The BAUER P-Filter systems meet and exceed the following international air quality standards| Germany: | DIN EN 12021 and PNEUROP 6611 |
|---|---|
| United Kingdom | BS 4275 (fire services), BS 4001, part 1.2 (diving) |
| France | Plonges Profondes Offshore |
| USA | CGA Grade D+E, Navy Standard Federal Spec. Grade A+B |
| Canada | CSA |
With the BAUER P-filter system these international standards are met or clearly surpassed.
is integrated in the VERTICUS units. The oil and water emulsion collects in the bottom of the separator chamber and is drained manually or by means of an automatic condensate drain (optional).
The filter system P41 or P61 are part of the standard delivery scope of supply on the VERTICUS models. The filters are carefully selected to match the units' rate of flow and to provide long filter life. Drying agents in the filter cartridge absorbs the residual humidity and water vapours.
A - DRYING by adsorption of water vapour particles
B - NEUTRALISATION by adsorption of oil vapour and disturbing odours
C - MICRO FILTERING by binding suspended particles
BAUER's purification cartridges have a filter capacity of 1000 Nm (P41) or 1600 Nm (P61) at 200 bar (capacity in terms of free air delivery measured at 1 bar absolute, + 20 °C air temperature and + 30 °C final separator temperature).
Purchasing BAUER's P-filter system gives you a complete and functional air/gas purification system with:
| Model | Nominal pressure 1) | Flow rate 2) at 200 bar 3000 psig | Inlet / ambient temp. | Atmos. dew point | No. of filters | Conditionable airvolumes 3) | Connetion tube | DimensionsLWH mm / in. | Weight |
|---|---|---|---|---|---|---|---|---|---|
| P40 | 90-420 bar 1300-6000 psig | 450 l/min 15 Scfm | 5-50 °C 40-120°F | <-70 °C <-95°F | 1 | 1500 m 53000 cft | 8 mm | 700×160×700 27 2/3×6 1/4 ×27 2/3 | 40 kg 90 Ibs |
| P60 | 90-420 bar 1300-6000 psig | 600 l/min 20 Scfm | 5-50 °C 40-120°F | <-70 °C <-95°F | 1 | 2000 m 70000 cft | 8 mm | 700×160×900 27 2/3×6 1/4×35 1/2 | 40 kg 100 Ibs |
1) Different pressure range on demand
2) Free air delivery at 1 bar/14,5 psig and 20 °C/68°F
3) Cartridges for removal of oil and moisture at 30 °C/85°F and 200
bar/3000 psig in the final separator
| Filtersystem | P21 | P31 | P41 | P41 ECOSAFE | P61 | P61 ECOSAFE | P81 ECOSAFE |
|---|---|---|---|---|---|---|---|
| Ref. Filter housing | W7-7159 | W7-9873 | W6-2042 | W6-1685 | W6-1082 | W6-1224 | W6-1082 W |
See more products from this supplier.
Do you want to show products of your own company? Join FREE now!